AIR EMISSIONS IN NEW HAMPSHIRE:
MUNICIPAL SOLID WASTE INCINERATORS
Background
| Until the mid 1970s, most of New Hampshire's solid waste
was disposed of in landfills and town dumps. At that time, however, landfills
were reaching capacity and state and federal regulations were passed prohibiting
open burning at town dumps. The federal Resource Conservation and Recovery
Act (RCRA) was also enacted in 1976 encouraging non-polluting |
| methods of solid waste disposal. In response to the need
for an alternative solid waste disposal method, municipal solid waste (MSW)
incineration was implemented by a number of cities and towns throughout
New Hampshire. Incinerators burn MSW to reduce the volume of solid waste,
resulting in the production of ash which requires further disposal. Waste-to-energy
incinerators recover energy from the burning of MSW in the form of steam
for industrial needs, heating, or electricity generation. A key public
health and environmental concern related to MSW incineration is its emissions
to the air. |
 |
What is Municipal Solid Waste?
As used in this fact sheet, municipal solid waste includes primarily
residential wastes with some commercial, industrial and institutional wastes,
which are collected, transported, processed and disposed of by conventional
means. It does not include medical and infectious wastes or by-product
wastes from industrial processes (e.g., hazardous wastes). |
Municipal Solid Waste Incinerators in New Hampshire
As of September 2000, nine (9) MSW incinerators were operating in New
Hampshire, two of which are waste-to-energy facilities. These facilities
are listed below, along with their maximum yearly permit capacity (tons
of MSW per year), maximum daily design capacity (tons of MSW per day),
startup date, and number of New Hampshire municipalities served by the
facility.
|
Facility Location
|
Maximum Permit Capacity (tons per year)
|
Maximum Design Capacity (tons per day)
|
Start Up Date
|
# of Municipalities
|
| Concord |
210,000 |
575 |
1989 |
28 |
| Claremont |
83,950 |
230 |
1987 |
15 |
| MSW Incinerators: |
| Candia |
1,000 |
15 |
1977 |
1 |
| Hebron/Bridgewater
| 1,200 |
14 |
1977 |
2 |
| Litchfield
| 2,400 |
23 |
1983 |
1 |
| Nottingham
| 990 (est.) |
12 |
1973 |
1 |
| Ossipee
| 2,200 |
15 |
1987 |
1 |
| Sutton
| 642 (est.) |
2.5 |
1979 |
1 |
| Wilton |
1,000 |
30 |
1978 |
1 |
Air Emissions from MSW Incinerators>
Air emissions from municipal solid waste incinerators vary depending
on the contents of the solid waste and the completeness of combustion.
Pollutants from MSW combustion have potential health-related risks and
adverse environmental impacts. Pollutants from MSW burning often include:
- Acid gases - sulfur dioxide and hydrogen chloride;
- Particulate Matter - non-gaseous portion (unburned MSW, unburned fuel, sulfur compounds, carbon, ash, dust);
- Carbon Monoxide - a product of incomplete combustion;
- Nitrogen oxides - contributes to smog, acid rain, particulate formation and regional haze;
- Metals - Beryllium, cadmium, manganese, mercury, nickel, vanadium; and
- Dioxins and furans - generic terms for groups of related toxic compounds.
State-of-the-art combustion facilities are equipped with pollution control
equipment that greatly reduces air emissions. Pollutants present in air
emissions can be controlled in several ways:
(1) Separation Prior to Combustion - Separation of certain materials
prior to incineration is the best way individuals can reduce harmful air
emissions. In particular, metals emissions are reduced if separation occurs
before incineration. Suspected contributors to harmful emissions include
lead soldered items, household batteries, lead acid batteries, fluorescent
lights, home thermostats, and certain plastics. New Hampshire law restricting
pollutant content in batteries and packaging has greatly reduced the pollutant
content of the waste stream.
(2) Combustion Control - Proper combustion conditions are important
in controlling air emissions and can limit the formation of dioxins and
furans. "Good combustion practices" include continuous monitoring and control
(manual and/or computerized), operator training and proper facility design,
construction and maintenance. The New Hampshire
Department of Environmental Services (DES) monitors these parameters through
its construction permit and permit-to-operate programs.
(3) Removal of Pollutants from Gases by Using Post-Combustion Pollution
Control Equipment - Fabric filters (baghouses) and electrostatic precipitators
(ESPs) are often used to collect and remove particulate emissions. Units
to control the emissions of acid gases include scrubbers used in conjunction
with fabric filters, and dry sorbent injection followed by cooling and
an ESP.
State and Federal Regulations to Control Air Emissions from MSW Incinerators
In addition to many efforts to limit toxic compounds from entering the
waste stream, DES regulates air emissions from MSW incinerators under the
New
Hampshire Code of Administrative Rules and the federal Clean Air Act
Amendments of 1990. Regulatory applicability is dependent upon the combustion
capacity of the facility, the location of the facility, the type and level
of emissions, and the date the facility was constructed or modified. State
rules require MSW incinerators with a design capacity greater than or equal
to 1000 pounds per hour to obtain an air emissions permit. All permitted
MSW incinerators are regulated for opacity (how dark or thick the smoke
is), particulate matter emissions, and toxic air emissions. MSW incinerators
with a throughput capacity of 4,000 pounds per hour or 48 tons per day
or greater are also regulated for hydrogen chloride emissions. In addition,
MSW incinerators with a throughput capacity of 100 tons per day or greater
that are subject to the federal regulation for MSW are required to meet
a mercury emissions standard of 0.028 milligrams per dry standard cubic
meter (mg/dscm).
With the passage of the federal Clean Air Act Amendments of 1990, the
U.S. Environmental Protection Agency (EPA) was charged with establishing
standards for new MSW incinerators and guidelines for existing MSW incinerators.
In December 1995, EPA issued standards and guidelines for MSW incinerators
with a combustion capacity greater than or equal to 38.5 tons per day,
which applies to four facilities in New Hampshire. Portions of these standards
were vacated by the U.S. Court of Appeals, D.C. Circuit, in March 1997.
Only standards applying to municipal waste combustors with capacity of
250 tons per day or greater were retained. EPA proposed to re-establish
the regulations for small MSW incinerators (capacity to burn between 35
and 250 tons per day) in August 1999. Federal requirements were established
for:
- Particulate matter;
- Opacity;
- Acid Gases - Sulfur dioxide (SO2) and hydrogen chloride (HCl);
- Metals - Cadmium (Cd), lead (Pb), and mercury (Hg);
- Organics - Dioxins and furans;
- Good Combustion Practices - Operator training and certification, carbon monoxide (CO) concentration measurements, flue gas temperature control, and load level control; and
- Performance Testing and Monitoring.
For More Information
For more information on municipal solid waste incinerators in New Hampshire
and federal and state regulations for controlling air emissions from these
facilities, please contact the:
New Hampshire Department of Environmental Services
Air Resources Division
(603) 271-1370
http://www.des.state.nh.us
|